Jandy no longer supports parts for their older systems. In fairness to Zodiac/Jandy, they feel that a pool professional should do this. 2023 Zodiac Pool Systems LLC - All rights reserved. AquaPure Guide d'installation et mode d'emploi. If not, contact a pool professional. Apple is not a participant or sponsor of this promotion. Report PoolGate Gold Supporter TFP Guide Jun 7, 2017 7,748 Damascus, MD Pool Size 29000 We could have gotten by with the PLC700 but this gave us a larger cell. Please try again later. They are built of a rugged glass-filled polypropelene material, have standard Jandy unions, and are NSF listed for your commercial application. #1. ORP / External Control Interface 2. You use the% generation control to adjust the actual amount of chlorine generated to meet your pools chlorine need. Ordered one off Amazon and got it replaced todaywith the help of the hubby. This corrosion increases the resistance of the connection and generates a lot of heat due to the high current of 6 to 8 amps. Includes: 1 - Power Interface Board Assembly. Check the water balance as usual. The problem is that the O-rings can leak, which creates a corrosive mix of water, salt, hydrogen gas and chlorine gas. Cell trisensor senses temperature, salinity and flow. This AquaPure foundation power center pack is designed to se with Zodiac Jandy AquaPure PureLink cell kit. Will salt from the salt water chlorinator deteriorate the metal components in my pool? A member had the problem of his Aquapure resetting to 35% every time it was powered on by the timer. Being relatively adept, I chose to install this myself. See Section 5, Operating Instructions section of the owner's manual. When a FREEZE CONTROLLER is used on pump equipment and the chlorinator is run through the winter, turn the CHLORINE PRODUCTION down to 10 - 20%. On the other hand if the readings are different then it indicates that there is a problem with the board. Drop in the Best When You Replace the Rest. ZODIAC is a registered trademark of Zodiac International, S.A.S.U., used under license. The Jandy AquaPure APUREM salt-water chlorine sanitizing systems use salt water to deliver high-performance water sanitation with uncompromised performance, reliability and hydraulic efficiency. Turn on pump. Earn at least $9 in pool perks for this item by joining Pool Perks. We promise to never spam you, and just use your email address to identify you as a valid customer. Press and hold the test buttons marked salinity and R-temp. Amazon.com: Zodiac R0403200 Control Box Cover Replacement for Zodiac AquaPure APURE1400 Plastic Control Center : Patio, Lawn & Garden . The Jandy AquaPure salt-water chlorine sanitizing systems use salt water to deliver high-performance water sanitation with uncompromised performance, reliability and hydraulic efficiency. Am I correct in assuming that the box contains the internal components such as the control, A: FREE delivery Feb 16 . An excellent system. Jandy APUREM AquaPure Salt Generator Power Center, Brand new returned unit - Never installed just opened, Create a Saltwater Oasis in Your Backyard, Automatic self-cleaning feature ensures consistent operation and extended lifespan of the cell, Exclusive Tri-Sensor technology provides reliable electronic water flow detection to sustain maximum performance, even at very low flow rates, Digital salinity read-out for accurate salt-level indication, Flow, temperature and status readings provide instant feedback on the current operation, When combined with PureLink power centers, AquaLink and AquaPure work together for the ultimate in pool sanitizing and remote operation convenience, Seamless communication with AquaLink Control systems enables easy monitoring of salt levels and convenient, precise sanitizer output settings, Note: The salt cells are sold separately Many of these units have been shipped with bad circuit boards, as my pool professional was told by the Jandy tech. Dont use the little adaptor card between the cord plug and the circuit board. Drop in the Best When You Replace the Rest. Tri-Sensor R-kits will ship first, beginning with date code 10/6/14. Jandy Zodiac AquaPure PLC1400 PLC 1400 Saltwater Cell Kit AQUA PURE 352 8 offers from $1,209.92 Product Description This control box cover is designed to use with Zodiac AquaPure plastic control center model APURE700. You need the Aquapure system with the control box and cell. You are using an out of date browser. Select your subscriptions from a range of popular titles. It appears that Aqualink stops talking to Aquapure when the Aqualink water temperature sensor is inoperative.[12]. Jandy Aquapure Clormatic III Front Panel Control Board Psd306-01 Apure1400 . Why You Should Only Work With A Qualified Professional. Consult your pool professional regarding use of a sequestering agent. 1 - Face Plate, Control Center, APUREM. The item you are trying to purchase is currently out of stock.Please enter your name, email, and phone number below. See Section 4.7 of the owner's manual. (567 gm/24 Hr.). The basic Jandy Aqualink RS System involves FIVE key elements: 1) Order your System Level. Integrates very well with Aqualink. For a better experience, please enable JavaScript in your browser before proceeding. While the salt water chlorinator prevents the user from needing to add chlorine to the pool on a regular basis, some maintenance, in regards to water balancing, will still need to be accomplished. Sitemap | Do I still need to use granular chlorine with my Salt water chlorinator? If the Aquapure is disconnected from the Aqualink, then you should be able to set chlorine production from the front panel on the Aquapure. You know what? First thing to check is the cord. Reviewed in the United States on December 6, 2014. Make sure that the salt is very well mixed by brushing thoroughly at least 5 times. Some members add dielectric grease to the pins when they do their annual work on the filter and check the cell. The AquaPure has a 3 hour polarity cycle time (3 hours one polarity, 3 hours reverse polarity). The cell cannot be repaired even though the plates may have life left in them. Jandy / Zodiac PLC1400 Replacement Cell Kit for AquaPure / PureLink 1400. If the readings are correct then the board is O.K. It's always important to test the salinity before adding salt to determine how much salt should be added. If the cell is old, just get the PLC1400 kit. Jandy AquaPure 1400 Chlorine Generator Quick Specs View Detailed Specs Power: 1.25 lbs/day 90-Day / 1 Year Limited Warranty 8000 Hours Rated Lifespan 40000 Gallons Max Capacity Description Reviews Specs Controls Cell Warranty "The Heavy-Duty Standard for Maximum Performance" We selected and analyzed the cases involving AEDs. Add To Cart. For all your hard to find pool and spa parts, including above ground spa parts, , Copyright 2023 Pool and Spa Parts Depot. Free shipping for many products! This is why changing this parameter is reserved for the pool professional. Provide your account email address to receive an email to reset your password. Prime pump if necessary. Both cells use the same Power Center box. No warranty when purchased online. Thanks, Problem solved. Rely on its sturdy design and simple features to create your saltwater oasis. However there is a jumper on the Power Interface Board that is connected for the 1400 cell and cut for the 700 cell. The percentage setting will control how much the cell runs during the production cycle.[5]. Do I have to add salt every month with a salt water chlorinator? It measures temperature, salinity and flow. When the tri-sensor fails the salinity will be incorrect or you will get a no-flow error. 1 - Mounting Bracket, User Interface, APUREM. The flow portion of the Flow/Temp/Salinity Sensor is a backup device only. Either a short wait or a reboot resolve this. If chlorine output at lowest setting is still excessive then the salt water chlorinator system is oversized for the pool. The system will beep when you push it and then at 5 seconds and again at 10 seconds. It may not display this or other websites correctly. Brand new! Press and hold the test buttons marked salinity and R-temp. Reviewed in the United States on April 8, 2017. Rely on its sturdy design and simple features to create your saltwater oasis. Natural stone can be visually altered over time. The 700 cell has half the number of plates as the 1400 cell. JavaScript is disabled. The water balance will be less threatened, because only pure chlorine is added to the water. Brush down the affected walls and follow the directions in Section 5.4.1 of the owner's manual, Shocking. veggiebenz; Aug 8, 2022; Salt Water Chlorine Generators (SWG) Replies 2 . The production cycle time used for chlorine production (observationally) is 30 minutes. Adjust CHLORINE PRODUCTION to desired percentage. If more chlorine is needed, activating the Boost mode will override this cold water feature allowing chlorine production for 24 hours of operation. The required voltage is 120 to 240 volts. There was a problem completing your request. Jandy has the Jandy SP3P Dummy Cell Cleaning Kit that includes everything you need to remove, clean, store, and/or bypass your Jandy AquaPure 3-Port Salt Cell. Leslie's Pool Supplies does not share or sell personal info. Had to replace our original, 14 year old system which developed a front board issue. The cartridge must be replaced. 624537. Haha! Any new postings here are unlikely to be seen or responded to by other members. Note: Pool Pump and Control Center to AquaPure Must be Wired to Turn On and Off Together AquaPure Control Center 115/230VAC Electrical Supply Return to Pool From Pool Cell Pump Flow / Salinity Sensor Filter Heater To Drain (Backwash) Salt for Pool A q u a P u r e Options List 1. I'm upgrading my old AquaLink RS board to iAquaLink (with the IQ20-RS kit) and want to add an AquaPure 1400 salt generator. Product information Feedback Would you like to tell us about a lower price? . This warranty applies only to products installed and serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in which the product will be installed, where such state or local requirements exists. The center prong is the most common point of failure. Creating an account will enroll you in our Pool Perks loyalty program. Adjust total alkalinity to 80-120ppm. If you are switching from the 700 cell to the 1400 cell the JL1 jumper needs to be reconnected. Installation by a qualified pool professional required. There are numerous sites that have detailed information about the install. A separate communication will follow . Plug flow/temp/salinity sensor into connector on power center printed circuit board. (283 gm/24 Hr. I have upgraded the circuits boards as per Zodiac's support advice and they only made the problem less prevalent. All other firmware uses program B on the trisensor inline module. Quantity. Jandy Aquapure Control Center. Apple and the Apple logo are trademarks of Apple Inc., registered in the U.S. and other countries. When I check the water temperature on my Aqualink Control Center by quickly pressing the Pool Temp Boost button, it shows 85 degrees which I believe is correct. BigCommerce Premium Themes by PSDCenter. Check that unit is correctly wired for 240 VAC and connected to 240 VAC. Release the button after the 3rd beep. 1-800-537-5437. Choose from Pool and Spa Combo Systems. The mineral purifier cartridge may have ruptured. Polarity Inversion is what salt water chlorinators use to periodically remove scale from the electrode plates. Jandy switched to a 3-port cell design to aid in cleaning and plumbing flexibility and no longer makes 2-port cells. With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. Here is a test you can do to diagnose the trisensor. The AquaPure system is comprised of the following three component parts and an optional pool pump timer. You need to determine the correct Revisio, Q: PLASTIC CONTROL CENTER, MODELS 700 & 1400, PARTS - BIG DIPPER, ECLIPSE, TOTAL ECLIPSE, COMPLETE HIGHCAPACITY BROMINE & CHLORINE FEEDERS, KREEPY E-Z VAC & KREEPY KADET ACCESSORIES, ANTHONY "APOLLO RECTANGULAR FILTER GRIDS, ANTHONY "APOLLO RECTANGULAR FILTER GRIDS, AMERICAN PRODUCTS 5 & 8 POSITION TOP MOUNT, SPA DRAIN & ON/OFF VALVES FOR GARDEN HOSE, STANDARD HEATER UNION COMPONENTS - 1", 200 SERIES TYPHOON JETS - SCALLOPED, 2" FACE, 300 SERIES TYPHOON JETS - SCALLOPED, 3" FACE, 400 SERIES TYPHOON JETS - SCALLOPED, 4" FACE, 500 SERIES TYPHOON JETS - SCALLOPED, 5" FACE, RETRO FITTING LEN GORDON & OTHER CONTROLS, SPLASH PAK - 16, 18.5, & 24 SAND FILTERS, SPLASH PAK - 16, 18.5, & 24 SAND FILTERS, SPLASH PAK - 16, 18.5, & 24 SAND FILTERS, ANTHONY "APOLLO RECTANGULAR FILTER GRIDS, 200 SERIES TYPHOON JETS - SCALLOPED, 4" FACE, JANDY AQUAPURE | CONTROL BOX, PURE700 | R0402900, JANDY AQUAPURE | UNION NUT, 2" BLACK | R0412500, JANDY AQUAPURE | SALINITY METER | R0475300, JANDY AQUAPURE Ei | TS CONTROL PCB ASSY | R0512300, JANDY AQUAPURE | SPOOL PIECE, 2" BLACK UNIONS W/2803-009 | R0412800, POLARIS OZONATORS | 110/220V FOR UP TO 40,000 GALLONS | PZVII-2 | Discontinued, PENTAIR | HC-3330 HOUSING W/ 2098-0 | R172437, Pool and Spa Parts Depot | Swimming Pool Supplies. Be the first to review this product! Warning: shortening the polarity inversion time can wear the electrodes more than usual. After installing began to flash code of 181 & 172. The AquaPure salt-water chlorine sanitizing systems uses salt water to deliver water sanitation by generating chlorine. Jandy Pro Series AquaPure Power Pack AquaPure Salt Chlorinator Models Sanitizer Type Body Material Chlorine Connections Input Current Output Pool Size Recommended Flow Rate Maximum Pressure Recommended Tablets Chamber Capacity of Chlorine AquaPure Power Pack and PureLink Cell Kit, 7 Blade #PLC700 Saltwater Chlorinator PPGF eschewing the conventional role in traditional architectural hierarchies, this project acts as a catalyst to an overcrowded favela by bringing in social infrastructure and a connection between top . So it looks like it is good, but the water temp sensor is bad. Check for dirt or corrosion around DC cord contacts at cell. The Jandy AquaPure system consists of a AquaPure Power Center or PureLink Power Centers and either a PURE700 cell or a PURE1400 cell. JavaScript is disabled. Manufacturer SKU: 6967+. Jandy AquaPure control center for Jandy AquaPure PLC1400 and PLC700 chlorine generator cells. ZODIAC is a registered trademark of Zodiac International, S.A.S.U., used under license. After 24 hours, verify correct salt reading. Disconnect the flow salinity temp sensor from the front board. The audible alarm can be permanently disabled by removing the jumper from J2 on the control/power center Power Interface Board (PIB). You can check the calibration by doing the following below procedure. ORP / Freeze Control Unit 3 . For very hard water, some chlorinators can shorten the polarity inversion time (e.g. ZODIAC is a registered trademark of Zodiac International, S.A.S.U., used under license. The reason is simple: TFPC (Trouble Free Pool Care) is a methodology, not a product that you must purchase. Told me from the serial number on unit it should have been included. This may be necessary after heavy rains, backwashing and refilling, excessive splash out, etc. In Store Only. If its 02110A10 or 01220A15, you use program A, otherwise you use program B on the in-line module on the trisensor cord. We paired it with the APUREM. To avoid clogging the filter or damaging the control center and pump, do not add salt through the skimmer, main drain, or surge tank. JANDY AQUAPURE | CONTROL BOX, PURE1400 | R0403000, This product has a 1 year warranty from the manufacturer. NOTE: To clean the deposit (scale) on the electrolytic cell plates, see Section 6.3 of the owner's manual. The purer the salt, the better the life and performance of the electrolytic cell. Is it true that a salt water chlorinator provides chlorine-free water? ORP / Freeze Control Unit 3 . App Store is a service mark of Apple Inc. Google Play is trademark of Google, Inc. All other trademarks referenced herein are the property of their respective owners. The PureLink DC Cord is Jandy P/N R0402800. An optional "Spool" Piece (sold separately) used to be available to replace the cell during winterizing or cell maintenance. PLC700 (Cell Kit) This page was last edited on 21 November 2022, at 19:29. Power Center Compatible with Pentair IntelliChlor Pool, APPLIAFIT O-Ring Compatible with Jandy Zodiac R0357800 for CL, CV, DEL & DEV Series Filters (2-Pack), Tier1 Pool & Spa Filter Cartridge | Replacement for Dimension One 1561-00, Pleatco PDO75-2000, FC-3059, C-7367, Aladdin 17541 and More | 75 sq ft Pleated Fabric Filter Media, POOLPURE PDM28 Spa Filter Replaces Aquarest Dream Maker 461273 Hot Tub Filter, 2 Pack, SpaO2 Swimming Pool Aerators - Set of 2, ABS Injection Molding, Fit 1-1/2 FIP/MIP Threaded Return outlets, MAX Depth 19.7, Raise pH Without Changing Alkalinity, Crystal Clear Water, Less Chemicals, 1996-2023, Amazon.com, Inc. or its affiliates, Zodiac APUREM AquaPure Foundation Power Center Pack Replacement for Zodiac Jandy AquaPure PureLink Cell Kit. The manual says that the unit can be damaged, which could void the warranty. Determine the amount of salt necessary to add from an appropriate chart. Below 51F (11C), chlorine production is not permitted; operating the chlorinator in cold water might result in over-chlorinated pool water. Help others learn more about this product by uploading a video! Jandy AquaPure Control Center Parts |6 parts Frequently Purchased AquaPure Sanitizer Bottom Control Box Decal - R0404400 6 in stock $65.70 Add To Cart AquaPure Transformer - 115/230 Volts - R0481400 12 in stock $434.61 Add To Cart Control Box Cover, Pure1400 - R0403200 Allow 7-10 Days to Ship $185.91 Add To Cart Pure700 Control Box Cover - R0403100 The preferred salt is an evaporated, granulated, food quality, non-iodized salt. We had to replace the filter and pump body! Add salt to pool, 3.0 gpl to 3.5 gpl. Please use a different way to share. 20 points earns $1 Pool Perks reward. That error is low or no current to the cell. Recheck. The Jandy tri-sensor measures water flow, salinity, and water temperature. Used On Jandy AquaPure and ClorMatic Metal Control Box Systems. If there's a little adapter card between the old sensor cord and the circuit board, remove the adapter card. Check flow/temp/salinity sensor cable for damage. This site is protected by reCAPTCHA and the Google. You are using an out of date browser. When replacing the cell, it's important to replace the power cord so that the connections are clean and the resistance is minimized.[3]. This issue is with the trisensor, which is a separate part that installs in the cell. Is this and the aquapure plc 1400 saltwater cell kit compatible with the iaqualink 2.0 bo, A: Manually shock the pool following the directions in Section 5.4.1 of the owner's manual, Shocking. 2023 Zodiac Pool Systems LLC - All rights reserved. So the rating is 4 Stars. Very happy with seller. I bought one of these units from another vendor three years ago. The LCD should read 91 F or 33 C . Press the Salinity button and hold it until it beeps 3 times. All Rights Reserved. Had to down load from another site. Decrease the chlorine production rate adjustment button (arrow button A). Jul 7, 2021. Regular Price: $212.61. If the unit reads 2.8 gpl for salinity, then the unit has not been recalibrated. Turn on the chlorinator or increase the chlorine production percentage. Most common is the center pin.[9]. In addition, the AquaPure threads are proprietary and Jandy does not offer replacement proprietary unions (the "male" piece). We have never winterized before. Field switchable to power all PureLink, ClorMatic and Nature2 Fusion Soft cell kits, LCD monitoring of chlorine production, cell modes, salinity, temperature, water flow and diagnostics. See Section 6.3, Step 2 of the owner's manual. Free shipping for many products! See Section 6 of the owner's manual, User Maintenance Instructions. It displays the salt level in PPM on the display, and you can set the production rate (0-100%) on the LCD display, or you can integrate the system with a Jandy controller as I did. The controller will periodically change the direction of the cell current in order to eliminate the layers of scale that deposit on the electrode plates. Rely on its sturdy design and simple features to create your saltwater oasis. It is being practiced by thousands of pool owners just like you. The Sensor Interface Module is weatherproof and should be left outside (Fig 3a) of the power center enclosure (Fig 3b). contain additives. Jandy AquaPure Power Pack Features: Field switchable to power all PureLink, ClorMatic and Nature2 Fusion Soft cell kits 120V or 240V electrical connections LCD monitoring of chlorine production, cell modes, salinity, temperature, water flow and diagnostics Precision output adjustments I couldn't get one of the screws on the power panel off, Help Support TFP Trouble Free Pool is run by a dedicated group of volunteers that Read more, Hello , This is an inactive thread. $195.99. Item No. What is polarity inversion on a salt water chlorinator? The air temp went up. It is usually located underneath your Aqualink cabinet. It is being practiced by thousands of pool owners just like you. The PLC1400 cell is Jandy P/N R0452400. New, not old stock, in sealed box. See pages 13-14 in Jandy AquaPure Troubleshooting. Buy in monthly payments with Affirm on orders over $50. If the chlorinator is the correct size, then it's sufficient to sanitize the pool without adding granular chlorine. You will also find the cell sold alone at a lower price then the kit and it is tempting to buy only the cell. See Section 6.5 of the owner's manual, Winterizing. Add To Cart. Adjusting the audible alarm volume is also described on page 34 of the Installation Manual. If so, why the 2 different readings? For a better experience, please enable JavaScript in your browser before proceeding. Do Not use calcium chloride as a source of salt. Please try again. How does Aqualink RS Manage Solar and Gas Heating, Jandy IAqualink WiFi module with PDA Remote, iAqualink freeze protection - two specific questions, With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. Older Power Centers use a rectangle transformer P/N T1005 that is no longer available. (Take pool water sample to Pool Professional). VERY GOOD PRODUCT, indeed, easy to install. Apple and the Apple logo are trademarks of Apple Inc., registered in the U.S. and other countries. For all your hard to find pool and spa parts, including above ground spa parts, Control CenterThe control center converts AC electrical current to a low voltage DC current which is required by the cell to perform the electrolysis. If you have a No-Flow error try resetting the circuit breaker and re-calibrating the tri-sensor before you consider replacing it. Ensure that the flow/temp/salinity sensor is installed according to Section 3, Figure 11 of the owner's manual. Use Up and Down arrow keys to navigate search results. We could have gotten by with the PLC700 but this We made the decision to go to a salt water pool system. It includes aquapure control box only. The Jandy AquaPure salt-water chlorine purifying systems use salt water to deliver high-performance water purification with uncompromised performance, reliability and hydraulic efficiency. Error posting question. A common reason for the cell failing and getting error codes 120, 121 or 123 is one or more of the pins corroding and separating from its plate. The Salinity button C on the sanitizer user interface keypad can be used to determine salinity. We cannot guarantee the life span of this surface in the long term. This aquapure is use with PLC700 or PLc1400 for salt system only. The sensor connects to the same spot. . >PoolAndSpaPartsDepot.com is Open for Business! There was a problem adding this item to Cart. The Jandy AquaPure APUREM salt-water chlorine sanitizing systems use salt water to deliver high-performance water sanitation with uncompromised performance, reliability and hydraulic efficiency. Wichita Falls, TX. I've had a Jandy Aquapure 1400 since I opened the pool 4 years ago, and it's in the process of dying. The only difference is the new part has a ground wire that was attached to the common ground.[15]. Get 1 point for every $1 spent. Increase the system operating time per day. Wood Concrete Projects Built Projects Selected Projects Cultural Architecture Cultural Center Yuri Vital Iceberg Sao Paulo So Paulo Brazil Published on December 27, 2020 Cite: "Porto Seguro . Salt Water Pool Generator Control Center Model# APUREM Retail is $1000 with the pool water. An optional pool pump timer can be utilized to help control this function. Boost 24 Hour 100% Chlorine Production Cycle. Please consider. It uses 240V and 50/60hz Export. Register product at Jandy.com/registration. Does the Freeze Protect mode use the reading from the tri-sensor or the pool temperature sensor? Find many great new & used options and get the best deals for Jandy Aquapure Clormatic III Front Panel Control Board Psd306-01 Apure1400 at the best online prices at eBay! When the cell needs replacement you should replace the cell, tri sensor, and power cord. If the unit is not correctly installed you may get severe electrical shock or you may fry the system. There are beads at the bottom of my pool, what does it mean? Make sure that temp is above 60, salt is 3400, power cord is good and look in the cell at the plates with a good light from both ends to see if the plates are corroded. The remaining bromide in the pool will produce a white emulsion (chemical reaction). No instructions contained w/unit. Can I switch from bromide to salt water chlorination using the same water? I am concerned that this will affect Freeze Protect mode this winter. Please try again later. Scale formation on pool equipment. Aqualink prevents the Aquapure system from proper operation without a functioning water temperature signal from the Aqualink stand alone water temperature sensor, regardless of what the SWG flow sensor says. A great system, easy to install. It is possible his sensors are reversed. Natural stone liners or ornaments may be more susceptible to blemishes and erosion when using pool water treatments. Replace the Power Cord When you Replace the Cell, Replacing Old Square Jandy PLC700/1400 Cell, AquaPure Resets to 35% Everytime it is Powered On, AquaPure and PureLink Tri-Sensor Adapter Installation Kit Manual, Jandy AquaPure, PureLink & Nature Fusion Soft Workbook, https://www.troublefreepool.com/threads/need-intelliflo-and-jandy-aquapure-1400-folks.254612/post-2226671, https://www.troublefreepool.com/threads/plc1400-and-r0452400-compatible.260746/#post-2280305, https://www.troublefreepool.com/threads/six-month-old-jandy-plc1400-smoking-melting-rubber-wire-connector.198600/post-1752937, https://www.jandy.com/-/media/zodiac/global/downloads/h/h0325600.pdf, https://www.troublefreepool.com/threads/aquapure-cycle-time-wiki-correction.264622/#post-2321916, http://viewer.zmags.com/publication/1a29b06c#/1a29b06c/892, https://www.troublefreepool.com/threads/when-did-jandy-declare-war-on-diy.176586/post-1558946, https://www.troublefreepool.com/threads/jandy-old-square-salt-cell-replacement.201262/, https://www.troublefreepool.com/threads/jandy-aquapure-1400-error-120.236117/, https://www.troublefreepool.com/threads/aquapure-1400-receiving-error-code-123.46288/post-387518, https://www.troublefreepool.com/threads/jandy-aquapure-plc-700-not-producing-chlorine.220478/post-1929929, https://www.troublefreepool.com/threads/will-a-new-water-temp-sensor-fix-this-aquapure-swg-scenario.243392/, https://www.troublefreepool.com/threads/jandy-pda-wasnt-displaying-aquapure-info.194647/post-1715658, https://www.troublefreepool.com/threads/aquapure-keeps-resetting-to-chlorine-rate-35-from-pool-pump-timer.197670/post-1743853, https://www.troublefreepool.com/threads/jandy-power-center-transformer-replacement-aquapure.194422/, https://www.troublefreepool.com/wiki/index.php?title=Jandy_AquaPure_SWG&oldid=5928, PURE700 - 0.625 lb./24 Hr. Sign up for regular updates and to get the Jandy Drop-In Replacement Guide for model comparisons, dimensions, and more. To be more specific, do you mean the control board for the salt cell? After installing began to flash code of 181 & 172. If burnt connector contact authorized service representative. Many AquaPure display problems seem to get fixed by powering the Power Center and Aqualink panel if connected off at the circuit breakers, waiting a few minutes, and powering everything back on.[13]. Using genuine Jandy factory replacement parts helps to ensure the ongoing quality and reliability of our products. This piece has been discontinued and is no longer available.